Operating Parameters
B-2
Part 1120277_01
E 2012 Nordson Corporation
Standard
0 Enter Password
Description: A user-defined password that prevents unauthorized changes to
setpoint temperatures and operating parameters.
Value: 0 to 9999
Resolution: 1
Default Value: 4000
Format:
Use: This parameter only appears if a password is created using
parameter 11 and then enabled using parameter 10.
NOTE: The melter remains in the password-protected m ode for
two minutes after the last key press. After exiting the s etup
mode, attempting to re-enter the setup mode, even before two
minutes has elapsed, will require you to re-enter the password.
1 Total Hour s with Heaters On (Noneditable)
Description: A noneditable value that indicates the total number of hours that
the heaters have been on.
Value: 999,999 (using abbreviated convention described below)
Resolution: 1hour
Default Value: 0
Format:
Use: The right display indicates up to 9999 hours of heater operation.
When the accumulated heater hours reaches 10,000, the
display alternates every two seconds between the three left
most digits (thousands) and the three right digits (hundreds). For
example, 10,001 hours would be displayed as ”10,” for two
seconds and then ”001” fo r two seconds. T h e comma is present
if parameter 20, Temperature Units, is set to degrees
Fahrenheit. A period is present if p arameter 20 is set to degrees
Celsius.
2
Fault Log (Noneditable)
Description: Stores a record of the last ten faults.
Value:
Resolution:
Default Value: _-F0 (unused log entry)
Format: F1, F2, F3, and F4
Use: Use t he right-display scroll keys to review the log entries for t he
last ten faults. Empty log entries are indicated by “_-F0.” Refer to
Monitoring the Melter in Section 4, Operation.