Operating Parameters
B-3
Part 1120277_01
E 2012 Nordson Corporation
3 Change History Log (Noneditable)
Description: Records the last ten changes made to either the setpoint
temperatures or the operating parameters.
Value:
Resolution:
Default Value: P-_ (unused log entry)
Format: RefertoSection3,Installation, Review Parameter and Setpoint
Temperature Changes.
Use: Use the right-display key to review the log entries for the last ten
changes that were made to the operating parameters or the
setpoint temperatures. Empty log entries are indicated by “P-_.”
4 Ready Delay Time
Description: The amount of time that will elapse after all of the components
have reached their setpoint temperature before the ready LED
will turn on. The ready delay time only functions when the
temperature of the reservoir, at the time the melter is turned on,
is more than 27 C(50F) from its setpoint t emperature. The
ready delay time begins when all components are within 3 C
(5 F) of their respective setpoint temperature.
Value: 10 to 60 minutes
Resolution: 1minute
Default Value: 15 minutes
Format: Left display “rd.” Right display, minutes or seconds remaining.
Use: The ready delay allows the contents of the reservoir an
additional amount of time to heat before pump turns on.
NOTE: T he t ime remaining on the ready delay is indicated in
minutes in the right display at the end of every automatic scan
cycle. When the delay time reaches 1 minute, the time
remaining appears in seconds.
5 Service Interval Time
Description: The number of heater-on hours that must elapse before the
service LED turns on.
Value: 0 hours (disabled) to 8736 (one year)
Resolution: 1hour
Default Value: 500 hours
Format:
Use: Set the service interval time to signal a user-defined service
check or maintenance event, such as changing the filter. The
service LED will turn on after the pre-set time elapses. With the
melter in the scan mode, press t he Clear/Reset key to turn off
the service LED and reset the time.