Operating Parameters
B-4
Part 1120277_01
E 2012 Nordson Corporation
Standard (contd)
6 Service LED Heater Hours (Noneditable)
Description: A timer indicates how many more hours the heaters need to
remain on before the service LED illuminates (service required).
Value: 0 hours (disabled) to 9999
Resolution: 1hour
Default Value: 0
Format: —
Use: The service interval time (parameter 5) must be enabled before
this parameter will work.
NOTE: Heater hours accumulate whenever the heaters LED is
illuminated.
7 Motor Off Delay
Description: Determines the amount of time the motor will remain on after the
switching device turns off.
Value: 0 to 360 seconds
OR
----(infinite)
Resolution: seconds
Default Value: 0seconds
Format: —
Use: This parameter functions only when a switching device
(switched handgun hose, footswitch, etc.) is connected to the
switch receptacle.
8 Automatic Pump On
Description: Determines if the pump will turn on automatically when the
melter is ready.
Value: 0 = disabled or 1 = enabled
Resolution: —
Default Value: 1(enabled)
Format: —
Use: If Automatic Pump On is disabled, you must press the pump key
to turn the pump on.
If Automatic Pump On is enabled, the pump will turn on
automatically when the melter is ready.
NOTE: If Automatic Pump On is disabled (0) while the pump is
running, the pump will remain on until the pump key is pressed.