Operating Parameters
B-5
Part 1120277_01
E 2012 Nordson Corporation
10 Enable or Disable the Melter Password
Description: Activates or deactivates the melter password. When password
protection is activated, component setpoint temperatures or
melter operating parameters cannot be changed until a valid
password is entered using parameter 0.
Value: 0(disabled)
1(enabled)
Resolution:
Default Value: 0
Format:
Use: A password must first be created using parameter 11 before it
can be enabled or disabled using parameter 10.
11 Create Password
Description: A user-defined password that prevents unauthorized changes to
operating parameters or setpoint temperatures .
Value: 0 to 9999
Resolution: 1
Default Value: 5000
Format:
Use: RefertoSection4,Operation, Entering the Melter Password.
NOTE: When the password is created and enabled, parameter
10 will not appear again in the right display until the password is
entered.
12 Change Hose 1 Output to Electric Gun Activation
Description: Changes the proportioned 240 VAC current that is provided to
the hose 1 heater to a switched 240 VAC current that is used to
activate a manifold-mounted electric gun.
Value: 0(disabled)
1(enabled)
Resolution:
Default Value: 0(disabled)
Format:
Use: Use only when a Nordson manifold-mounted electric gun is
installed and a switching device is connected to the melter's
switch receptacle. Refer to the electric gun manual for
information on mounting and using the gun.