Troubleshooting
6-31
Part 1120277_01
E 2012 Nordson Corporation
+
--
Fault LED is illuminated >
F2 fault exists >
Reservoir key LED is illuminated >
No hot melt was recently added to the
reservoir
T.2.3
?
+
--
Is the resistance correct for
the reservoir heaters (2), melt
plate heaters (2), and the
manifold heater (1)? Refer to
Heater Specifications in
Section 8 for resistance
values.
+
--
Is the voltage across the
downstream side of fuses
F1 and F2 on the main
board 180-265 VAC?
Are the reservoir, melt
plate, and manifold
TRIACS functioning
properly?
?
Contact Nordson for
technical assistance.
+
--
Are the reservoir, melt
plate, and manifold RTDs
functioning properly?
Replace the reservoir, melt
plate, or manifold heater.
Check/correct house
voltage.
Replace the main board.
Replace the malfunctioning
RTD.
Stop.
+
--
Does replacing fuses F1/F2
(DS2), F5/F6 (DS3), or F7/F8
(DS5) on the main board and
then resetting the melter clear
the fault?
Replace the main board or
the melt plate/reservoir
thermostats.
+
--
Are any of indicators DS2,
DS3, or DS5 on the main
board illuminated?
+
--
Are the power relay and
the thermostat operating
properly?