Troubleshooting
6-33
Part 1120277_01
E 2012 Nordson Corporation
Fault LED is illuminated >
An F3 fault exists on a hose or gun >
The setpoint temperature was not
changed
T.2.4
Stop. Replace the main board or
the power module.
+
--
Does replacing the main
board and resetting the
melter clear the fault
Replace the display/CPU
board.
+
--
Does the fault clear if you
switch the faulting
hose/gun pair to a known
good hose/gun connector
and then reset the melter?
+
--
Does the fault clear if you
replace just the hose or just
the gun RTD and then
reset the melter?
+
--
Have LEDs DS12/DS13 on
the main board or LEDs
1-4 on the power module
stopped flashing?
Stop.
Replace the main board
(hose/gun 1 affected) or
replace the power module
(hose/gun 2 or 3).