Troubleshooting
6-35
Part 1120277_01
E 2012 Nordson Corporation
+
--
No faults >
Ready LED is not illuminated
T.3
Does the right display
indicate that components
are still heating up?
?
Wait for all components to
reach setpoint
temperature.
+
--
Wait for the input to initiate
the heaters or use the
Heaters key to manually
turn the heaters on.
Is the ready delay counting
down?
Wait for the ready delay to
count down.
Refer to Appendix B,
parameter 4.
+
--
The current clock schedule
has the heaters turned off.
Is the standby LED on?
The melter is in the
standby mode.
Refer to Standby Key in
Section 4, Operation.
Contact Nordson for
technical assistance.
+
--
Is the Heaters key LED
illuminated?
+
--
Is a remote input being
used to control the
heaters?
+
--
Is the clock LED on? Press the Heaters key to
turn the heaters on.
?
+
--
Replace the reservoir, melt
plate, or manifold heater.
Is the resistance correct for
the reservoir heaters (2), melt
plate heaters (2), and the
manifold heater (1)? Refer to
Heater Specifications in
Section 8 for resistance
values.