6.4. Torque Control Mode Operation
6.4.2. Analog Command Operation
2
2
3
3
t
t
y
y
p
p
e
e
2
2
5
5
t
t
y
y
p
p
e
e
6.4.2. Analog Torque Command Operation
l You may control directly the output torque of the Motor with analog torque command in the
torque control mode.
à You may set dead band to the command voltage.
(Refer to “6.4.2.1. Dead Band Set to Analog Command.”)
à Voltage of analog torque command is ± 10V. Offsetting analog command is possible
using an adjusting pod (VR1) on the front panel of the Driver Unit or setting parameter
AF. (Refer to “6.4.2.2. Offsetting Analog Command.”
à The parameter AC selects the polarity of command voltage. (See Table 6-15.)
à Relation between the command voltage and the output torque of the Motor may be
changed with parameter AGT.
(Refer to Figure 6-28.)
Table 6-15
DI setting AC setting Command voltage Rotational direction
0 1 +
CCW
0 1 –
CW
0 -1 +
CW
0 -1 –
CCW
1 1 +
CW
1 1 –
CCW
1 -1 +
CCW
1 -1 –
CW
Figure 6-31: Command voltage and output torque
- 10 V + 10 V
• Porality: + for CCW direction
(AC1)
• Porality: + for CW direction
(AC-1)
-10V
CCW
Max. torque
CW
Max. torque
+ 10 V
CCW
Max. torque
CW
Max torque
GT = 0.5
AGT = 1.0
AGT = 2.0
l Output torque of the Motor depends on the Motor type.