1.2. Terminology
u Classification of Driver Unit [23 type, 25 type, B3 type, etc.]
We classify the Driver Units along the function. They are distinguished by coding. Refer to the
table below for combinations of function and coding.
Table 1-1
Function
Type of position
sensor
Code Input / Output Code
Functional code of
Driver Unit
Basic type 3 B3 type
Absolute position
resolver
B
Extended I/O type
(with analog input)
5 B5 type
Basic type 3 23 type
Incremental position
resolver
2
Extended I/O type
(with analog input)
5 25 type
à Absolute position sensor : Home Return is not necessarily every time when the
power is turned on.
à Incremental position sensor : Home Return is required every time the power is turned
on.
à Basic type : A type of Driver Unit that does not have extended I/O
ports. Parameters set the required I/O signals.
à Extended I/O type : A type of Driver Unit that has extended I/O ports.
You can use multiple functions simultaneously.
This type can be operated by the analog command input.
u Reference Number of ESB Driver Unit for YSB Motor
Figure 1-1: Reference number of ESB Driver Unit for YSB Motor
M-ESB
Y
SB2020AB300
Driver Unit functional code
à Refer to “2.2.2. ESB Driver Unit for YSB Motor” for more details.