3.29.4 Fields
Field Function
7
TA_BB
TA_BB Power Supply Status:
0= Power supply is disabled or faulted.
1= Power supply is operating.
6-5
-
Reserved.
4
OVDD
OVDD (1.8V) Power Supply Status:
0= Power supply is disabled or faulted.
1= Power supply is operating.
3
-
Reserved.
2
VTT2
VTT2 (DDR block #2) Power Supply Status:
0= Power supply is disabled or faulted.
1= Power supply is operating.
1
VTT1
VTT1 (DDR block #1) Power Supply Status:
0= Power supply is disabled or faulted.
1= Power supply is operating.
0
GVDD
GVDD (1.2V) Power Supply Status:
0= Power supply is disabled or faulted.
1= Power supply is operating.
3.30 Clock Control Registers
The clock control registers control programmable clock synthesizers used to supply
clocks to the processor and associated peripherals.
3.31 Clock Speed 1 (CLK_SPD1)
Chapter 3 Qixis Programming Model
QorIQ LX2160A Reference Design Board Reference Manual, Rev. 0, 09/2018