3.32 Clock ID/Status (CLK_ID)
3.32.1 Address
Register Offset
CLK_ID 033h
3.32.2 Function
The CLK_ID register is used to identify the arrangement of the clock control registers.
Software should check CLK_ID register before attempting to interpret/control the clock
control registers.
3.32.3 Diagram
Bits
7 6 5 4 3 2 1 0
R ID
W
NONE 0000 0000
3.32.4 Fields
Field Function
7-4
-
Reserved.
3-0
ID
System Clock ID = 0000 (NONE)
CLK0= SYSCLK is fixed on this system.
3.33 Reset Control Registers
Chapter 3 Qixis Programming Model
QorIQ LX2160A Reference Design Board Reference Manual, Rev. 0, 09/2018
NXP Semiconductors 97