Refer to Settings in the Item Properties Display Area on page 8 - 74 that is described later in
this section for details on all settings.
8 When you have finished editing, click the OK button to exit the Edit Dialog Box Window.
l
Settings in the Item Properties Display Area
• Common Settings Area
Item
Setting value
[Factory default]
Description
Item title This is set to a
character string
that is not as-
signed to any other
item in the list
when the item is
added.
To change the title of the dialog box item, click the button
and enter the desired characters.
Display position X: 0 to 1920 [-]
Y: 0 to 1080 [-]
These are the coordinates of the upper left corner of the dialog
box item. The upper left corner of the dialog box is 0, 0.
The display position is also updated when you drag an item to
a new position in the Design Pane.
• Individual Setting Region
Numeric Box Setting Region
Item
Setting value
[Factory default]
Description
Data Type
• [Unit data (No.)]
• Unit data (ident)
• System data
• Scene variable
• System variable
Sets the unit specification method for targets for which to carry
out the numeric setting.
The setting details vary depending on the specification meth-
od.
Target unit No. 0 to No. of units in
the display target
scene - 1 [0]
This is available when Unit data (No.) or Unit data (ident) is
selected in the Data Type.
The units that are registered for the scene that is the target of
the normal dialog box will appear in the combo box. Select the
processing unit to set.
8 Setting Windows
8 - 74
FH/FHV Series Vision System User’s Manual (Z365-E1)