EasyManua.ls Logo

Omron M1 Series

Omron M1 Series
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power supply line
Standard applicable motor (kW)
Inverter model
Specifications
Molded case
circuit
breaker
(MCCB) or
earth leak-
age circuit
breaker
(RCD/ELCB)
rated cur-
rent
*1
Recommended wire size (mm
2
)
For main circuit
For control circuit terminal
Control power supply auxiliary input R0, T0
Main power
supply input
[L1/R, L2/S,
L3/T]
*2
Inverter
ground
[
]
*2*3
Inverter output [U, V, W]
*2
For DC reactor connection [P1, P(+)]
For braking resistor connection [P(+), DB]
*2
With DC reactor
Without DC reactor
With DC reactor
Without DC reactor
With DC reactor
Without DC reactor
Three
-
phas
e 400
V
0.4 3G3M1-
A4004
HHD 5 5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 0.75 -
0.75 HND
HD
ND
3G3M1-
A4007
HHD
1.1 HND
HD
1.5 ND
3G3M1-
A4015
HHD 10
2.2 HND
HD
ND
3G3M1-
A4022
HHD 10 15
3.0 HND
HD
ND
3G3M1-
A4030
HHD
4.0 HND 20
HD
ND
3G3M1-
A4040
HHD
5.5 HND 15 30
HD
ND
3G3M1-
A4055
HHD
7.5 HND 20 40 4 4
HD
3G3M1-
A4075
HHD
2 Design
2-72
M1 Series Standard Type User's Manual (I669)