Power supply line
Standard applicable motor (kW)
Inverter model
Specifications
Molded case
circuit
breaker
(MCCB) or
earth leak-
age circuit
breaker
(RCD/ELCB)
rated cur-
rent
*1
Recommended wire size (mm
2
)
For main circuit
For control circuit terminal
Control power supply auxiliary input R0, T0
Main power
supply input
[L1/R, L2/S,
L3/T]
*2
Inverter
ground
[
]
*2*3
Inverter output [U, V, W]
*2
For DC reactor connection [P1, P(+)]
For braking resistor connection [P(+), DB]
*2
With DC reactor
Without DC reactor
With DC reactor
Without DC reactor
With DC reactor
Without DC reactor
Three
-
phas
e 400
V
0.4 3G3M1-
A4004
HHD 5 5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 0.75 -
0.75 HND
HD
ND
3G3M1-
A4007
HHD
1.1 HND
HD
1.5 ND
3G3M1-
A4015
HHD 10
2.2 HND
HD
ND
3G3M1-
A4022
HHD 10 15
3.0 HND
HD
ND
3G3M1-
A4030
HHD
4.0 HND 20
HD
ND
3G3M1-
A4040
HHD
5.5 HND 15 30
HD
ND
3G3M1-
A4055
HHD
7.5 HND 20 40 4 4
HD
3G3M1-
A4075
HHD
2 Design
2-72
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C

Related product manuals