Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit
W161 Braking Resistor Thermal Monitor
0.0 to 100.0%
0.0 - %
W178 Number of Startups
0.00 to 655.35
(1.00 = 10000 times)
0.00 - -
W179 Total RUN Time Monitor
0 to 655350 hour
0 - h
W180 Tuning Progress
0 to 100 %
0 - %
W202 Do not use - - - -
W203 Do not use - - - -
4-1-3
Parameter z (Alarm Information 1)
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit
Z00
Second Last Alarm Info. Output
Frequency
0.00 to 655.35 Hz
0 - Hz
Z01
Second Last Alarm Info. Output
Current
0.00 to 99.99 A
0 - A
Z02
Second Last Alarm Info. Output
Voltage
0 to 1000 V
0 - V
Z03
Second Last Alarm Info. Torque
Monitor
-999 to 999
0 - %
Z04
Second Last Alarm Info. Frequen-
cy Command
0.00 to 655.35
0 - Hz
4 Parameter List
4-40
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C