Clear Selection of Favorite Function Code (H03 = 8)
When “8: Clear selection of favorite function code” is set to Data Initialization (H03), the registered
state of favorite parameters is cleared (canceled). The values of parameters registered as favorite
parameters are not initialized. For details on registering favorite parameters, refer to 7-7-6 User Pa-
rameter Setting Function on page 7-80.
T
o register to favorite parameters, hold the
key down during display of a parameter. To indicate
that a parameter has been registered as a favorite parameter, the decimal point LED of the upper-
most digit lights. If the same operation is performed one more time, the parameter is removed from
user preferences, and the decimal LED of the uppermost digit turns OFF.
5-1-3
User Preference Dataset (Registration/Protection)
Set User Preference Dataset Registration/Protection by the following parameters. When “4: Restore
user defined data” is set to Data Initialization (H03), parameters are initialized using the saved user
preference datasets.
Parameter No. Function name Data Default data Unit
H193
User Preference Data-
set Registration
0: Disable
1: Store
0 -
H194
User Preference Data-
set Protection Function
Selection
0: Unprotected
1: Protected 0 -
Related function Data Initialization (H03)
The set values of parameters that have been changed from the factory defaults can be saved (regis-
tered) as user preference dataset. For parameters also that have not been changed from the factory
defaults, factory defaults can be saved (registered) as user preference dataset. Note, however
, that
the following parameters are not targeted for saving as user preference datasets.
Main Circuit Capacitor Service Life Coef
ficient (Measurement V
alue) (H42)
Main Circuit Capacitor Service Life Coefficient (Initial Value) (H47)
Service Life of Main Circuit Capacitor Remaining Time (H77)
Cumulative Run Time of Cooling Fan (H43)
Cumulative Run Time of Capacitors on Printed Circuit Boards (H48)
1st Startup Count for Motor (H44)
2nd Startup Counter for Motor (A52)
1st Cumulative Motor Run Time (H94)
2nd Cumulative Motor Run Time (A51)
User Preference Dataset Protection Function Selection (H194)
Monitor Exclusive Parameters (M, W Parameters)
Save user preference dataset by the following procedure. To change User Preference Dataset Reg-
istration (H193) and User Preference Dataset Protection Function Selection (H194), the “
key +
/ key” must be pressed simultaneously with each of the parameter values displayed.
Step 1: Set “0: Unprotected” (default value) to User Preference Dataset Protection Function Selec-
tion (H194).
5 Basic Settings
5-8
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
BrandOmron
ModelM1 Series
CategoryInverter
LanguageEnglish

Related product manuals