Step 2: Select User Preference Dataset Registration (H193). “0: Disable” is displayed as the value
of H193.
Step 3: When User Preference Dataset Registration (H193) is set to “1: Protected,” registration of
the user preference dataset is started. During registration, “SAVE” is displayed, and the value re-
turns to 0 when registration is completed.
Step 4: To protect the user preference dataset, set “1: Protected (save prohibited)” to User Prefer-
ence Dataset Protection Function Selection (H194).
To set all user preference datasets to the factory defaults, initialize parameters by Data Initialization
(H03) “1: Initialize all parameters,” and then register the datasets by User Preference Dataset Regis-
tration (H193).
5 Basic Settings
5-9
M1 Series Standard Type User's Manual (I669)
5-1 Display and Initialization
5
5-1-3 User Preference Dataset (Registration/Protection)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C