When Drive Control Selection (F42) = 15, 16 (synchronous motor)
The set values of the following parameters are overwritten with the following values according to
the new settings after changing Load Mode Selection (F80).
Manual Torque Boost V
oltage (F09)
Power supply Model
Capacity
[kW]
Manual Torque Boost Voltage (F09)
Set value
Load Mode Selection (F80)
0: HHD 1: HND 3: HD 4: ND
Three-phase 200 V
3G3M1-A2001 0.1 8.4 6.7 - -
3G3M1-A2002 0.2 8.4 6.7 - -
3G3M1-A2004 0.4 7.1 4.0 - -
3G3M1-A2007 0.75 6.8 3.5 - -
3G3M1-A2015 1.5 6.8 4.9 - -
3G3M1-A2022 2.2 6.8 4.5 - -
3G3M1-A2037 3.7 5.5 4.1 - -
3G3M1-A2055 5.5 4.9 3.4 - -
3G3M1-A2075 7.5 4.4 2.7 - -
3G3M1-A2110 11 3.5 2.1 - -
3G3M1-A2150 15 2.8 1.6 - -
3G3M1-A2185 18.5 2.2 1.3 - -
Three-phase 400 V
3G3M1-A4004 0.4 7.1 4.0 7.1 4.0
3G3M1-A4007 0.75 6.8 3.5 6.8 3.5
3G3M1-A4015 1.5 6.8 4.9 6.8 4.9
3G3M1-A4022 2.2 6.8 4.5 6.8 4.5
3G3M1-A4030 3.0 6.8 4.5 6.8 4.5
3G3M1-A4040 4.0 5.5 4.1 5.5 4.1
3G3M1-A4055 5.5 4.9 3.4 4.9 3.4
3G3M1-A4075 7.5 4.4 2.7 4.4 2.7
3G3M1-A4110 11 3.5 2.1 3.5 2.1
3G3M1-A4150 15 2.8 1.6 2.8 1.6
3G3M1-A4185 18.5 2.2 1.3 2.2 1.3
3G3M1-A4220 22 2.2 1.1 2.2 1.1
Single-phase 200 V
3G3M1-AB001 0.1 8.4 6.7 - -
3G3M1-AB002 0.2 8.4 6.7 - -
3G3M1-AB004 0.4 7.1 4.0 - -
3G3M1-AB007 0.75 6.8 3.5 - -
3G3M1-AB015 1.5 6.8 4.9 - -
3G3M1-AB022 2.2 6.8 4.5 - -
3G3M1-AB037 3.7 5.5 - - -
5-2-3
Slip Compensation
The slip compensation function calculates the torque generated by the motor to infer the slip amount.
As a result of this calculation, the drop in motor rotation speed can be compensated for to suppress
the drop in motor rotation speed. This is useful for improving the speed control accuracy of the motor.
To enable the slip compensation function, select “0: V/f control” or “3: V/f control with speed sensor” at
Drive Control Selection (F42/A14), then set 1 at Slip compensation Function Selection (H442), and set
5 Basic Settings
5-16
M1 Series Standard Type User's Manual (I669)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C