1-3
Specifications
1-3-1
Standard Specifications
Three-phase 200-V Class
HHD: Heavy load, HND: Light load
Item Three-phase 200 V
Model
(3G3M1-A2□□□)
001 002 004 007 015 022 037 055 075 110 150 185
Maxi-
mum
applica-
ble mo-
tor ca-
pacity
*1
kW HHD 0.1 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5
HND
0.2 0.4 0.75 1.1 2.2
3
*7
5.5
*7
7.5 11 15 18.5 22
HP HHD
1/8 1/4 1/2 1 2 3 5
7
1/2
10 15 20 25
HND
1/4 1/2 1
1
1/2
3 4
7
1/2
10 15 20 25 30
Rated
output
capacity
[kV
A]
*2
200 V HHD
0.3 0.6 1 1.7 2.8 3.8 6.1 8.7 11 16 21 26
HND 0.5 0.7 1.2 2.1 3.3 4.2 6.8 10 14 19 24 30
240 V HHD 0.4 0.7 1.2 2.1 3.3 4.6 7.3 10 14 20 25 32
HND
0.5 0.8 1.5 2.5 4.0 5.0 8.1 12 17 23 29 37
Rated input voltage
*3
Three-phase 200 to 240 V, 50/60 Hz
Rated input cur-
rent [A]
*4
HHD 1.1 1.8 3.1 5.3 9.5 13.2 22.2 31.5 42.7 60.7 80 97
HND
1.8 2.6 4.9 6.7 12.8 17.9 28.5 42.7 60.7 80 97 112
Rated output voltage Three-phase 200 to 240 V (with AVR)
Rated output cur-
rent [A]
*5
HHD 1 1.6 3 5 8 11 17.5 25 33 47 60 76
HND
1.3 2 3.5 6 9.6
12
*7
19.6
*7
30 40 56 69 88
Braking torque
[%]
*6
HHD 150 100 70 40 20
HND
75 53 68 48
29
*7
27
*7
15
Braking
resistor
circuit
Regenerative
braking
Built-in braking resistor circuit (discharge resistor separately mounted)
Minimum con-
nection resist-
ance [
Ω]
100 to 120 40 to 120
33
to
120
20
min.
15
min.
10
min.
8.6
min.
4
min.
Short circuit current rating
[kA]
100
Weight [kg] 0.5
0.5 0.6 0.8 1.4 1.4 1.7 3.8 4 5.3 5.4 11
Dimensions (Width ×
Height) [mm] 68×127 110×130
140
×
130
180×220 220×260
250
×
400
Dimensions (Depth) [mm] 98 113 145 156 171 203 203
*1. The maximum applicable motor capacity is given for a standard four-phase motor. When selecting an inver-
ter, select not just by kW but also ensure that the inverter rated output current is greater than the motor rat-
ed current.
*2. In calculating the rated capacity
, the rated output voltage is assumed to be 200 V or 240 V.
1 Overview
1-11
M1 Series Standard Type User's Manual (I669)
1-3 Specifications
1
1-3-1 Standard Specifications