1st Cumulative Motor Run Time (H94)
2nd Cumulative Motor Run Time (A51)
User Preference Dataset Protection Function Selection (H194)
Monitor Exclusive Parameters (M, W Parameters)
Initialize All Parameters (Except I/O and Communications) (H03 = 5)
When “5: Initialize all parameters (except I/O and communications)” is set to Data Initialization
(H03), the following parameters excluding I/O and communications are initialized to their factory de-
faults.
Input Terminal [DI1] Function Selection to Input Terminal [DI7] Function Selection (E01
E05, E98,
E99)
Output Terminal [DO1] Function Selection, Output Terminal [DO2] Function Selection (E20, E21)
Output Terminal [ROA, ROB] Function Selection (E27)
RS-485 Communication Station No. Selection (y11)
Operation Selection on Communication Error (y12)
RS-485 Error Detection Timer (y13)
RS-485 Communication Baud Rate (y14)
RS-485 Communication Parity Bit Selection (y16)
RS-485 Communication Timeout Time (y18)
RS-485 Communication Response Interval Time (y19)
Data Clear Processing for Communications Error (y95)
Also, the following parameters are not initialized.
Main Circuit Capacitor Service Life Coefficient (Measurement Value) (H42)
Main Circuit Capacitor Service Life Coefficient (Initial Value) (H47)
Service Life of Main Circuit Capacitor Remaining Time (H77)
Cumulative Run Time of Cooling Fan (H43)
Cumulative Run Time of Capacitors on Printed Circuit Boards (H48)
1st Startup Count for Motor (H44)
2nd Startup Counter for Motor (A52)
1st Cumulative Motor Run Time (H94)
2nd Cumulative Motor Run Time (A51)
User Preference Dataset Protection Function Selection (H194)
Monitor Exclusive Parameters (M, W Parameters)
Clear Alarm History (H03 = 7)
When “7: Clear alarm history” is set to Data Initialization (H03), the alarm history and data at the
time of the alarm, multiple alarm information, light alarm history, and number of occurrences are
cleared to set to an alarm non-occurring state.
The alarm information of parameters (refer to 7-1-4 Alarm information on page
7-18) is initialized.
5 Basic Settings
5-7
M1 Series Standard Type User's Manual (I669)
5-1 Display and Initialization
5
5-1-2 Data Initialization

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron M1 Series and is the answer not in the manual?

Omron M1 Series Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage3-phase 200 to 240 VAC
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
CommunicationRS-485, Modbus RTU
EnclosureIP20
Cooling MethodFan Cooled
Operating Temperature-10°C to +50°C
Humidity5-95% (non-condensing)
AltitudeUp to 1000m
Frequency Range0.5-400 Hz
Storage Temperature-20°C to +65°C