Parameter
No.
Function name Monitor or data range
Default
data
Setting
during
RUN
Unit
M58 Rotor Angle Monitor
0.0 to 359.9º
0 - deg
M59 Motor Electronic Thermal Monitor
0 to 100%
0 - %
M61
Inverter Internal Air Temperature
Monitor
-3276.8~3276.7
0 - degC
M62 Fin Temperature Monitor
-3276.8~3276.7
0 - degC
M63 Load Factor Monitor
-327.68 to 327.67
0 - %
M64 Motor Output Monitor
-327.68 to 327.67 % of rated
power
0 - %
M65 Motor Output Monitor on Alarm
-32768 to 32767
0 - -
M66 Speed Detection Monitor
-32768 to 32767
0 - -
M67
Transmission Error Transaction
Code for RS485 Port
1: Improper FC (Non-existent
parameter block specified)
[R
TU]
2: Improper address (Non-ex-
istent parameter number
specified) [R
TU]
3: Improper data (Range error)
[R
TU]
7: NAK (Link priority, no right,
write disabled) [RTU]
71: Checksum error, CRC er-
ror
72: Parity error
73: Framing error, overrun er-
ror, buffer full
0 - -
4 Parameter List
4-17
M1 Series Standard Type User's Manual (I669)
4-1 List of Monitors by Group
4