EasyManua.ls Logo

Omron M1 Series

Omron M1 Series
808 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit
X10
Second Last Alarm History/
Number of Consecutive Same
Alarms
32 hex (50) : ErC Magnetic
pole position detection error
33 hex (51) : ErF Data save
error in case of undervoltage
34 hex (52) : d0 Excessive po-
sitioning deviation
35 hex (53) : ErP (RS-485
communications error, Option
card)
38 hex (56) : Ero Position con-
trol error
39 hex (57) : ECF EN circuit
failure
3A hex (58) : CoF PID feed-
back disconnection detected
3B hex (59) : dbA Braking re-
sistor overheat
44 hex (68) : ErU Support tool
communication disconnection
46 hex (70) : OH6 Inrush cur-
rent prevention resistor over-
heat
FD hex (253) : Lok Locked by
password
FE hex (254) : Err Mock alarm
(Subcode = 9998)
0 -
-
X11 Second last Multiple Alarm2
0000 to FFFF Hex
0 - -
X12 Second Last Multiple Alarm3
0000 to FFFF Hex
0 - -
X13 Second Last Alarm Sub Code
0 to 9999
0 - -
X14
Second Last Multiple Alarm Sub
Code
0 to 9999
0 - -
4 Parameter List
4-55
M1 Series Standard Type User's Manual (I669)
4-1 List of Monitors by Group
4
4-1-4 Parameter X (Alarm Information 2)

Table of Contents

Related product manuals