12-19
12 Troubleshooting
NJ-series CPU Unit Software User’s Manual (W501)
12-2 Troubleshooting
12
12-2-3 Error Table
90010000 hex Clock
Changed
The clock time was
changed.
The clock time was changed. page 12-42
90020000 hex Time Zone
Changed
The time zone was
changed.
The time zone was changed. page 12-42
90080000 hex Variable
Changed to
TRUE with
Forced
Refreshing
Changing a variable
to TRUE with forced
refreshing was
specified.
Changing a variable to TRUE
with forced refreshing was
specified by the user.
page 12-42
90090000 hex Variable
Changed to
FALSE with
Forced
Refreshing
Changing a variable
to FALSE with
forced refreshing
was specified.
Changing a variable to FALSE
with forced refreshing was
specified by the user.
page 12-43
900A0000 hex All Forced
Refreshing
Cleared
Clearing all forced
refreshing values
was specified.
Clearing all forced refreshing
values was specified by the
user.
page 12-43
900B0000 hex Memory All
Cleared
All memory was
cleared.
A user with Administrator rights
cleared all of the memory.
page 12-43
900C0000 hex Event Log
Cleared
The event log was
cleared.
The event log was cleared by
the user.
page 12-44
900F0000 hex
(Ver. 1.03)
Automatic
Transfer
Completed
The automatic
transfer was com-
pleted.
The automatic transfer was
completed.
page 12-44
90110000 hex Power
Turned ON
The power supply
was turned ON.
The power supply was turned
ON.
page 12-44
90120000 hex Power Inter-
rupted
The power supply
was interrupted.
The power supply was inter-
rupted.
page 12-45
9013
0000 hex Operation
Star
ted
Operation was
started.
A command to start operation
was received.
page 12-45
90140000 hex Operation
Stopped
Operation was
stopped.
A command to stop operation
was received.
page 12-45
90150000 hex Reset Exe-
cuted
A reset was exe-
cuted.
A reset command was
received.
page 12-46
90160000 hex User Pro-
gram Execu-
tion ID Write
The user program
execution ID was
set or changed in
the CPU Unit.
A user with Administrator rights
changed the user program exe-
cution ID that is set in the CPU
Unit.
page 12-46
90180000 hex All Controller
Errors
Cleared
All current errors
were cleared.
All current errors were changed
by the user.
page 12-46
90190000 hex Forced
Refreshing
Cleared
Clearing a forced
refreshing value
was specified.
Clearing a forced refreshing
value was specified by the user.
page 12-47
901A0000 hex
(Ver. 1.03)
Backup
Started
A backup operation
was started.
A backup operation was
started.
page 12-47
901B0000 hex
(Ver. 1.03)
Backup Com-
pleted
The backup opera-
tion ended nor-
mally.
The backup operation ended
normally.
page 12-48
901C0000 hex
(Ver. 1.03)
Restore
Operation
Started
A restore operation
started.
A restore operation started. page 12-48
901D0000 hex
(Ver. 1.03)
Restore
Operation
Completed
The restore opera-
tion ended nor-
mally.
The restore operation ended
normally.
pa
ge 12-49
Event code Event name Meaning Assumed cause
Level
Reference
Maj Prt Min Obs Info