4 Controller Setup
4-6
NJ-series CPU Unit Software User’s Manual (W501)
Task Settings
The Task Settings are used to add and set up tasks.
4-2-3 Task Settings
Parameter
Setting
group
Description Set value Default
Update
timing
Changes in
RUN mode
Task Type Sets the task type. Primary peri-
odic task
Priority-16
periodic task
Priority-17
periodic task
Priority-18
periodic task
Priority-8
event task
Priority-48
event task
Primary peri-
odic task
When down-
loaded to
CPU Unit
Not allowed.
Execution Pri-
ority
Sets the task execution
priority.
Automatically
set according
to the task
type.
Primary peri-
odic task: 4
When down-
loaded to
CPU Unit
Not allowed.
Task Name Sets the task name. Text string Primary peri-
odic task: Pri-
maryTask
Periodic
tasks:
PeriodicTask0
Event tasks:
EventTask0
When down-
loaded to
CPU Unit
Not allowed.

Table of Contents

Other manuals for Omron NJ Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NJ Series and is the answer not in the manual?

Omron NJ Series Specifications

General IconGeneral
Program CapacityUp to 128 MB
SD Card SlotYes
Power Supply Voltage24 VDC
Motion ControlYes
USB Ports1
Operating Temperature0°C to 55°C
Communication InterfacesEthernet/IP, EtherCAT, USB
Safety FunctionOptional
Storage Temperature-20°C to 75°C
Communication PortsUSB
DimensionsVaries by model
WeightVaries by model

Related product manuals