Appendices
A-56
NJ-series CPU Unit Software User’s Manual (W501)
*1 This system-defined variable was added for unit version 1.03 of the CPU Unit.
*1 This system-defined variable was added for unit version 1.03 of the CPU Unit.
*1 This system-defined variable was added for unit version 1.03 of the CPU Unit.
Functional Classification: Backup
*1 This system-defined variable was added for unit version 1.03 of the CPU Unit.
Variable name
_Card1VefySta
*1
Member name
.Active
Meaning Active Flag Global/local Global
Function TRUE when a verification is in progress.
Note You cannot use this system-defined variable in the user program. Use it in CIP message communications
to read the status from an HMI or host computer.
Data type Structure: _sVEFY_STA, Member: BOOL Range of values TRUE or FALSE
R/W access Read Retained Not retained. Network Publish Published.
Usage in user program Not possible. Related instruc-
tions
---
Variable name
_Card1VefySta
*1
Member name
.VefyRslt
Meaning Verify Result Flag Global/local Global
Function TRUE if the data was the same. FALSE if differences were found.
Note You cannot use this system-defined variable in the user program. Use it in CIP message communications
to read the status from an HMI or host computer.
Data type Structure: _sVEFY_STA, Member: BOOL Range of values TRUE or FALSE
R/W access Read Retained Not retained. Network Publish Published.
Usage in user program Not possible. Related instruc-
tions
---
Variable name
_Card1VefySta
*1
Member name
.Err
Meaning Error Flag Global/local Global
Function TRUE when processing a verification ended in an error.
Note You cannot use this system-defined variable in the user program. Use it in CIP message communications
to read the status from an HMI or host computer.
Data type Structure: _sVEFY_STA, Member: BOOL Range of values TRUE or FALSE
R/W access Read Retained Not retained. Network Publish Published.
Usage in user program Not possible. Related instruc-
tions
---
Variable name
_BackupBusy
*1
Meaning Backup Function Busy Flag Global/local Global
Function TRUE when a backup, restoration, or verification is in progress.
Data type BOOL Range of values TRUE or FALSE
R/W access Read Retained Not retained. Network Publish Published.
Usage in user program Possible. Related instruc-
tions
---

Table of Contents

Other manuals for Omron NJ Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron NJ Series and is the answer not in the manual?

Omron NJ Series Specifications

General IconGeneral
Program CapacityUp to 128 MB
SD Card SlotYes
Power Supply Voltage24 VDC
Motion ControlYes
USB Ports1
Operating Temperature0°C to 55°C
Communication InterfacesEthernet/IP, EtherCAT, USB
Safety FunctionOptional
Storage Temperature-20°C to 75°C
Communication PortsUSB
DimensionsVaries by model
WeightVaries by model