12-11
12 Pulse Outputs
CP2E CPU Unit Software User’s Manual(W614)
12-1 Overview
12
12-1-2 Flow of Operation
z Pulse Output Wiring
Nîš…îš…-type (Example: Sinking outputs)
Sîš…îš…-type (Example: Sinking outputs)
It is necessary to wire an external power supply to Sîš…îš…-type CPU Units.
Connect a DC24V external power supply between V+ and V- in order to use terminals 00 and 01 on
terminal block CIO 100.
Note COM corresponding to CIO 100.00 and CIO 100.01 has been internally connected with V- for sinking
output models, with V+ for sourcing output models.
PULS
PULS
SGN
SGN
(
+
)
(
+
)
(
-
)
(
-
)
+
-
CP2E CPU Unit built-in output terminals
Pulse output
Direction output
24-VDC
power
supply
100.00
100.01
100.02
100.03
COM
Servo Drive for 24-VDC input
Instruction pulse mode = feed pulse
and forward/reverse signal
PULS
PULS
SGN
SGN
(
+
)
(
+
)
(
-
)
(
-
)
+
V+
COM
V-
-
CP2E CPU Unit built-in output terminals
Pulse output
Direction output
24-VDC
power
supply
Servo Drive for 24-VDC input
Instruction pulse mode = feed pulse
and forward/reverse signal
100.00
100.01
100.02
100.03

Table of Contents

Other manuals for Omron SYSMAC CP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CP Series and is the answer not in the manual?

Omron SYSMAC CP Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CP Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals