12 Pulse Outputs
12-48
CP2E CPU Unit Software User’s Manual(W614)
z PLC Setup
Note The Use define origin operation setting is read from the PLC Setup when the power supply is turned ON.
z DM Area Settings
• Settings for PLS2 for Fixed-distance Positioning (D0 to D7)
• Settings for PLS2 to Return to Start (D10 to D17)
• Number of Repeats of Fixed-distance Positioning Operation (D20)
Preparations
Setting
Use define origin operation for pulse output 0.
Setting details Address Data
Acceleration rate: 1,000 Hz/4 ms D0 #03E8
Deceleration rate: 1,000 Hz/4 ms D1 #03E8
Target frequency: 50,000 Hz D2 #C350
D3 #0000
Number of output pulses: 10,000 pulses D4 #2710
D5 #0000
Starting frequency: 0 Hz D6 #0000
D7 #0000
Setting details Address Data
Acceleration rate: 300 Hz/4 ms D10 #012C
Deceleration rate: 200 Hz/4 ms D11 #00C8
Target frequency: 50,000 Hz D12 #C350
D13 #0000
Number of output pulses: 0 pulse D14 #0000
D15 #0000
Starting frequency: 100 Hz D16 #0064
D17 #0000
Setting details Address Data
Number of repeats of fixed-distance positioning
operation (number of PCBs in stocker)
D20 #000F

Table of Contents

Other manuals for Omron SYSMAC CP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CP Series and is the answer not in the manual?

Omron SYSMAC CP Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CP Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals