Appendices
A-8
CP2E CPU Unit Software User’s Manual(W614)
ACCUMULA-
TIVE TIMER
TTIM
(BCD)
--- TTIM(087)/TTIMX(555) operates an incrementing timer with units
of 0.1-s. The setting range for the set value (SV) is 0 to 999.9 s for
TTIM(BCD) and 0 to 6,553.5 s for TTIMX(Binary).
TTIMX
(Binary)
---
LONG TIMER TIML
(BCD)
--- TIML(542)/TIMLX(553) operates a decrementing timer with units
of 0.1-s that can time up to approx. 115 days for TIML(BCD) and
49,710 days for TIMLX(Binary).
TIMLX
(Binary)
---
COUNTER CNT
(BCD)
--- CNT/CNTX(546) operates a decrementing counter. The setting
range for the set value (SV) is 0 to 9,999 for CNT(BCD) and 0 to
65,535 for CNTX(Binary).
CNTX
(Binary)
---
Instruction Mnemonic Variations Symbol/Operand Function
TTIM(087)
N
S
N: Timer number
S: Set value
Reset
input
Timer
input
Timer input
Timer PV
SV
Reset input
PV
maintained.
Timing
resumes.
Completion
Flag
ON
OFF
0
ON
OFF
ON
OFF
TTIMX(555)
N
S
N: Timer number
S: Set value
Reset
input
Timer
input
TIML(542)
D1
D2
S
D1: Completion Flag
D2: PV word
S: SV word
Timer input
Timer P
V
SV
Completion Flag
(Bit 00 of D1)
ON
OFF
0
ON
OFF
TIMLX(553)
D1
D2
S
D1: Completion Flag
D2: PV word
S: SV word
CNT
N
S
N: Counter number
S: Set value
Reset
input
Count
input
SV
Count input
Counter PV
Completion
Flag
Reset input
ON
OFF
ON
OFF
0
ON
OFF
CNTX(546)
N
S
Count
input
Reset
input
N: Counter number
S: Set value

Table of Contents

Other manuals for Omron SYSMAC CP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CP Series and is the answer not in the manual?

Omron SYSMAC CP Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CP Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals