EasyManua.ls Logo

Omron VARISPEED F7 - Analog Reference Cards; Digital Reference Cards

Omron VARISPEED F7
389 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-149
6
Analog Reference Cards
When using a AI-14B or A1-14U analog reference card, set parameter b1-01 (Reference selection) to 3
(Option Card).
The AI-14B provides 3 bi-polar input channels with 14-bit (plus sign) A/D conversion.
If b1-01 is set to 1 and F2-01 is set to 0, the channel 1 and 2 replace the analog inputs A1 and A2. A1 becomes
the frequency reference input and the function of A2 can be selected using parameter H3-09. In this case no
digital input can be set for the Option/Inverter selection function (H1- = 2).
If b1-02 is set to 3 and F2-01 is set to 1, the sum of three input channels becomes the frequency reference
value.
The AI-14U provides 2 unipolar inputs channels with 14-bit A/D conversion. Channel 1 is a voltage input and
channel 2 is a current input. The sum of the channels 1 and 2 is the frequency reference. F2-01 does not need
to be set for the AI-14U option card.
Related Parameters
Digital Reference Cards
When using a DI-08 or DI-16H2 Digital Reference Card, set b1-01 (Reference selection) to 3 (Option Card).
The DI-16H2 can be used to set a frequency using a 16-bit digital reference.
The DI-08 can be used to set a frequency using a 8-bit digital reference.
Related Parameters
Parameter
No.
Name
Factory
Setting
Change
during
Opera-
tion
Control Methods
V/f
V/f with
PG
Open
Loop
Vector
Closed
Loop
Vector
b1-01Frequency reference source selection 1 No QQQQ
F2-01Bi-polar or uni-polar input selection 0 No AAAA
Parameter
No.
Name
Factory
Setting
Change
during
Opera-
tion
Control Methods
V/f
V/f with
PG
Open
Loop
Vector
Closed
Loop
Vector
F3-01 Digital input selection 0 No AAAA
o1-03Frequency units of reference setting and monitor 0 No AAAA

Table of Contents

Other manuals for Omron VARISPEED F7

Related product manuals