EasyManua.ls Logo

Omron VARISPEED F7 - Hunting-Prevention Function

Omron VARISPEED F7
389 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-44
6
Hunting-Prevention Function
The hunting-prevention function suppresses hunting when the motor is operating with a light load. This func-
tion can be used in the V/f control modes only.
If high response has the priority to vibration suppression this function should be disabled (n1-01 = 0).
Related Parameters
Adjusting the Hunting-Prevention Gain (n1-02)
Normally it is not necessary to change this setting. Adjust the value under the following circumstances:
If vibrations occur under light load condition increase the setting.
If the motor stalls reduce the setting.
Parameter
No.
Name
Factory
Setting
Change
during
Opera-
tion
Control Methods
V/f
V/f with
PG
Open
Loop
Vector
Closed
Loop
Vector
n1-01 Hunting-prevention function selection 1 No A A No No
n1-02 Hunting-prevention gain 1.00 No A A No No