Install PCIe Riser in Server Nodes
3.
Return the server node to operation.
a.
Install the server node top cover.
See “Installing the Server Node Top Cover” on page 245.
b.
Install the server node into the system.
See “Installing a Server Node Into the System Chassis” on page 246.
c.
Reconnect any data cables to the PCIe card connectors on the system rear
panel.
d.
Power on the server node.
See “Powering On Oracle Database Appliance Version 1” on page 249.
4.
Clear PCIe riser faults.
a.
Log in to the Oracle ILOM CLI as root.
b.
Type:
-> show /SP/faultmgmt
Oracle ILOM lists all known faults. For example:
SP/faultmgmt
Targets:
0 (/SYS/MB/RISER)
Properties:
Commands:
cd
show
c.
To clear PCIe riser faults, use the set command. For example:
-> set /SYS/MB/RISER clear_fault_action=true
Are you sure you want to clear /SYS/MB/RISER (y/n)? y
Set 'clear_fault_action' to 'true'
Appendix A • Servicing the Oracle Database Appliance Version 1 181