How to Set a Threshold Alert for SSD Endurance (CLI)
type = data
use = data
rpm = --
device = c0t5001E82002630190d0
pathcount = 2
interface = SAS
endurance = 100%
endurance_updated = 2014-3-3 22:04:14
locate = false
offline = false
As shown above, disk-015 is at 100% which indicate a new SSD. The remaining lifetime
estimate decreases as the disk is used.
How to Set a Threshold Alert for SSD Endurance (CLI)
Use the following procedure to set a threshold alert for SSD endurance.
1.
To set a threshold alert for SSD endurance, use the following CLI commands:
tarpon:configuration alerts> thresholds
tarpon:configuration alerts thresholds> create
tarpon:configuration alerts threshold (uncommitted)> set
statname=ssd.endurance[ssd]
statname = ssd.endurance[ssd] (uncommitted)
2.
To list the properties of the threshold alert, use the following CLI command:
tarpon:configuration alerts threshold (uncommitted)> list
Properties:
uuid = <generated on commit>
statname = ssd.endurance[ssd] (uncommitted)
type = normal
limit = (unset)
minpost = 5 minutes
days = all
window_start = none
window_end = 00:00
frequency = 5 minutes
minclear = 5 minutes
Note - The remaining fields are set the same way you would set them for any other threshold
alert.
Servicing the Hardware 21