EasyManua.ls Logo

Oracle DE2-24 - Page 98

Default Icon
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
How to Replace a ZS3-4 Memory
the Maintenance > Hardware screen of the BUI, and click on the right-arrow icon on the
controller. Then click DIMMs to locate the faulted component, indicated by the warning icon
.
1.
Shut down the controller using one of the power-off methods described in “How
to Power off the Controller” on page 41.
2.
Extend the controller from the rack as described in “How to Extend the Storage
Controller from the Rack” on page 41.
3.
Remove the top cover as described in “How to Remove the Top
Cover” on page 42.
4.
To locate the DIMM you want to service, press the Fault Remind Button on the
storage controller.
The following illustration shows the Fault remind button on the ZS3-4 controller.
98 Oracle ZFS Storage Appliance Customer Service Manual • February 2016

Table of Contents

Other manuals for Oracle DE2-24

Related product manuals