FPΣ User's Manual
8.6 Program Controlled Communication
205
After the scan start code "%S
C
R
" has been sent from the FPΣ side, the scan result is returned
from the Micro-Imagechecker as the response.
Communication format settings for Micro-Imagechecker A100/A200
To set the communication mode and transmission format settings for the Micro-Imagechecker,
select "5: Communication" under "5: ENVIRONMENT" on the main menu, and set the
following items.
No. Name Set value
51
Communication mode Normal Mode
52 RS232C
Baud rate:
Length:
Stop bit:
Parity:
Flow Control:
9600bit/s
8
1
Odd
None
53
Serial Output
Output:
Invalid Digit:
Read End:
Process End:
Numerical Calculation:
Judgment:
5 Column
Repl. 0
None
None
Output
Output
NOTE
If "Del" is specified for the invalid processing parameter, zero suppression
processing will be carried out on the output data, and the output format will
be changed. Always make sure "Repl. 0" is specified.
When outputting data to an external device, numerical calculation is
required, so "Out" should be specified for the "Numerical calculation"
parameter.
With the above settings, the following data will be output from the Micro-Imagechecker:
C
R
1012345
1
2
3
4
1
Terminator (end code)
3
Judgment output No. 2 0=NG
2
Results of numerical calculation No. 1
4
Judgment output No. 1 1=OK