EasyManuals Logo

Panasonic FPG-COM4-A User Manual

Panasonic FPG-COM4-A
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #297 background imageLoading...
Page #297 background image
Appendix
FPΣ User's Manual
280
12.2.1.1 Maximum Counting Speed and Output Frequency
The maximum counting speed of the high-speed counter function and the maximum output
frequency of the pulse output function are determined by the number of channels used and
the combination of the two functions. The same channel cannot be used by more than one
function.
Channel used Maximum output frequency [kHz]
High-speed counter Pulse output
High-speed
counter
Pulse output
1-phase 2-phase No interpol.
CH0 CH1 CH2 CH3 CH0 CH2 CH0 CH2
Inter
pol.
1-
phase
2-
phase
No
interpol.
Interpol.
X
50
X
50
X
50
X
50
X X
30
X
X
30
X
X
30
X X
30
X
X
30
X X
30
X X X
20
X
X X
20
X X
X
20
X X X
20
X
20
X
X
20 15
X X
20 15
X X X
20 15
X
20
X
X
20 15
X
X
20 15
X X
X
20 15
X X
15
X
100
X
3)
X
30
60
X
3)
X
X
20
45
X X X
X
20
30
X X
15 45

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FPG-COM4-A and is the answer not in the manual?

Panasonic FPG-COM4-A Specifications

General IconGeneral
BrandPanasonic
ModelFPG-COM4-A
CategoryController
LanguageEnglish

Related product manuals