EasyManua.ls Logo

Panasonic KX-HDV130

Panasonic KX-HDV130
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description Specifies the retransmission interval, in seconds, for "18x" responses.
Value Range 0, 1–600 (0: Disable)
Default Value 0
SIP_SUBS_EXPIRE_n
Parameter Name Example SIP_SUBS_EXPIRE_1, SIP_SUBS_EXPIRE_2
Value Format INTEGER
Description Specifies the length of time, in seconds, that the subscription remains
valid. This value is set in the "Expires
" header of the SUBSCRIBE
request.
Value Range 1–4294967295
Default Value 3600
SUB_INTERVAL_RATE_n
Parameter Name Example SUB_INTERVAL_RATE_1, SUB_INTERVAL_RATE_2
Value Format INTEGER
Description Specifies the percentage of the "expires
" value after which to refresh
subscriptions by sending a new SUBSCRIBE message in the same
dialog.
Value Range 1–100
Default Value 50
SUB_RTX_INTVL_n
Parameter Name Example SUB_RTX_INTVL_1, SUB_RTX_INTVL_2
Value Format INTEGER
Description Specifies the interval, in seconds, between transmissions of
SUBSCRIBE
requests
when a subscription results in failure (server no
reply or error reply).
Value Range 1–86400
Default Value 10
SIP_P_PREFERRED_ID_n
Parameter Name Example SIP_P_PREFERRED_ID_1, SIP_P_PREFERRED_ID_2
Value Format BOOLEAN
Document Version 2015-12 Administrator Guide 247
5.3.22 SIP Settings

Table of Contents

Other manuals for Panasonic KX-HDV130

Related product manuals