HOLD_ALARM_GAIN
Value Format INTEGER
Description Specifies the gain, in decibels, of the hold alarm.
Value Range -24–24 (dB)
Default Value 0
CW_TONE1_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of call waiting tone 1 using
2 whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 425
CW_TONE1_GAIN
Value Format INTEGER
Description Specifies the gain, in decibels, of call waiting tone 1.
Value Range -24–24 (dB)
Default Value 0
HOLD_TONE_FRQ
Value Format Comma-separated Integer
Description Specifies the dual-tone frequencies, in hertz, of the hold tone using 2
whole numbers separated by a comma.
Value Range 0, 200–2000 (0: No tone)
Default Value 425
HOLD_TONE_GAIN
Value Format INTEGER
Description Specifies the gain, in decibels, of the hold tone.
Value Range -24–24 (dB)
Default Value 0
Document Version 2015-12 Administrator Guide 289
5.3.32 Tone Settings