Description Specifies the minimum period, in seconds, that STUN Binding
Requests can be sent by the CPE for the purpose of maintaining the
binding
in the Gateway. This limit applies only to Binding Requests sent
from the UDP Connection Request address and port, and only those
that do not contain the BINDING-CHANGE attribute.
Note
• This setting is available only when
"ANNEX_G_STUN_ENABLE" is set to "Y".
Value Range 1–3600
Default Value 30
UDP_CON_REQ_ADDR_NOTIFY_LIMIT
Value Format INTEGER
Description Specifies the minimum time, in seconds, between Active Notifications
resulting from changes to the "UDPConnectionRequestAddress
" (if
Active Notification is enabled).
Value Range 0–65535
Default Value 0
DEVICE_PROVISIONING_CODE
Value Format STRING
Description Specifies the device provisioning code for use with TR-106
parameters.
Value Range Max. 64 characters
Default Value Empty string
5.3.10 XML Settings
XMLAPP_ENABLE
Value Format BOOLEAN
Description Specifies whether to enable the XML application feature.
Value Range
• Y: Enable XML application
• N: Disable
Default Value
N
Web User Interface Reference Enable XMLAPP (Page 99)
Document Version 2015-07 Administrator Guide 209
5.3.10 XML Settings