EMERGENCY_CALLx
Parameter Name Example EMERGENCY_CALL1, EMERGENCY_CALL2, …, EMERGENCY_CALL5
Value Format STRING
Description Specifies the emergency number. (Up to 5 emergency numbers)
Value Range Max. 32 characters (except &, ", ', :, ;, <, >)
Default Value Empty string
Web User Interface Reference 1–5 (Page 141)
CALL_REJECTIONx
Parameter Name Example CALL_REJECTION1, CALL_REJECTION2, …, CALL_REJECTION
30
Value Format STRING
Description Specifies the rejected number per line. (Up to 30 rejected numbers)
Value Range Max. 32 characters (except &, ", ', :, ;, <, >)
Default Value Empty string
Web User Interface Reference 1–30 (Page 141)
CLICKTO_ENABLE_n
Parameter Name Example CLICKTO_ENABLE_1, CLICKTO_ENABLE
_2, ...,
CLICKTO_ENABLE_6
Value Format BOOLEAN
Description Specifies whether to enable or disable Click to Dial/Answer/Hold
functions.
Value Range
• Y: Enable
• N: Disable
Default Value
N
Web User Interface Reference Enable Click to Call (Page 146)
CALLPARK_NOTIFICATION_ENABLE_n
Parameter Name Example CALLPARK_NOTIFICATION_ENABLE_1,
CALLPARK_NOTIFICATION_ENABLE
_2, ...,
CALLPARK_NOTIFICATION_ENABLE_6
Value Format BOOLEAN
Description Specifies whether to respond to call park notifications from the server.
306 Administrator Guide Document Version 2015-07
5.3.34 Call Control Settings