Value Range
Y: Send un-REGISTER
N: Does not send
Default Value
N
SIP_SESSION_TIME_n
Parameter Name Example SIP_SESSION_TIME_1, SIP_SESSION_TIME
_2, ...,
SIP_SESSION_TIME_6
Value Format INTEGER
Description Specifies the length of time, in seconds, that the unit waits before
terminating SIP sessions when no reply to repeated requests is
received. For details, refer to RFC 4028.
Value Range 0, 60–65535 (0: Disable)
Default Value 0
Web User Interface Reference Enable Session Timer (RFC 4028) (Page 127)
SIP_SESSION_METHOD_n
Parameter Name Example SIP_SESSION_METHOD_1, SIP_SESSION_METHOD
_2, ...,
SIP_SESSION_METHOD_6
Value Format INTEGER
Description Specifies the refreshing method of SIP sessions.
Value Range 0–2
0: reINVITE
1: UPDATE
2: AUTO
Default Value 0
Web User Interface Reference Session Timer Method (Page 127)
SIP_TIMER_T1_n
Parameter Name Example SIP_TIMER_T1_1, SIP_TIMER_T1
_2, ..., SIP_TIMER_T1_6
Value Format INTEGER
Description Specifies the default interval, in milliseconds, between transmissions of
SIP messages. For details, refer to RFC 3261.