Description x=1–200
Specifies
a particular Facility Action for the flexible key. No facility action
will be taken for the button if the string is empty or invalid.
Note
• If this parameter is specified, "DSS_BUTTON_QUICK_DIALx"
should be an empty string.
Value Range X_PANASONIC_IPTEL_LINE,
X_PANASONIC_IPTEL_ONETOUCH,
X_PANASONIC_IPTEL_ACD,
X_PANASONIC_IPTEL_WRAPUP,
X_PANASONIC_IPTEL_BLF,
X_PANASONIC_IPTEL_LINESTATUS,
X_PANASONIC_IPTEL_FORWARD,
X_PANASONIC_IPTEL_PHONEBOOK,
X_PANASONIC_IPTEL_CALLLOG,
X_PANASONIC_IPTEL_PARARING,
X_PANASONIC_IPTEL_HOTELING,
X_PANASONIC_IPTEL_TRANSFER,
X_PANASONIC_IPTEL_BLINDTRANSFER,
X_PANASONIC_IPTEL_CONFERENCE,
X_PANASONIC_IPTEL_DIRECTPICKUP,
X_PANASONIC_IPTEL_CALLPARK,
X_PANASONIC_IPTEL_PARKRETRIEVE
Default Value Empty string
Web User Interface Reference Type (Page 156)
DSS_BUTTON_FACILITY_ARGx
Parameter Name Example DSS_BUTTON_FACILITY_ARG1, DSS_BUTTON_FACILITY_ARG2,
...,
DSS_BUTTON_FACILITY_ARG200
Value Format STRING
Description x=1–200
Specifies an optional argument associated with the specified Facility
Action for the flexible key.
Value Range Max. 34 characters
Default Value Empty string
Web User Interface Reference Parameter (Page 157)
DSS_BUTTON_LABELx
Parameter Name Example DSS_BUTTON_LABEL1, DSS_BUTTON_LABEL2, ...,
DSS_BUTTON_LABEL200
Value Format STRING
288 Administrator Guide Document Version 2015-07
5.3.32 DSS Key Settings