2.3 System Data Control
Feature Guide 245
2.3 System Data Control
2.3.1 PC Programming
Description
Although many PBX features can be programmed using a proprietary telephone (PT) ( 2.3.2 PT
Programming), a PC connected to the PBX can use the KX-TDA Maintenance Console software to program
in further detail. System programming, diagnosis, and data upload/download can be performed either
through on-site programming or remote programming.
1) On-site Programming: Programming that is performed using an on-site PC connected directly to
the PBX.
2) Remote Programming: Programming that is performed using an off-site PC that connects to the
PBX via a CO line.
1. Connection Methods for On-site Programming
Method Description
Required
Hardware
Serial Interface
(RS-232C port)
The PC is connected to the PBX via the Serial Interface
(RS-232C port) of the PBX.
USB The PC is connected to the PBX via the USB port located
on the MPR card, or to the USB port of a USB Module
attached to a digital proprietary telephone (DPT).
MPR card
(preinstalled) or
USB Module
LAN The PC is connected to the PBX via Ethernet cable to the
CTI-LINK card.
CTI-LINK card
Modem
(connected to SLT
port)*
The PC is connected to a modem, which is then connected
to an SLT port of the PBX. Use the modem to dial the
floating extension number assigned to the analog remote
maintenance feature ( Modem Floating Extension
Number [811]) to access the PBX.
RMT card and
user-supplied
modem
ISDN TA
(connected to ISDN
extension line)*
The PC is connected to an ISDN terminal adapter (TA),
which is then connected to the PBX via an ISDN extension
line. Use the TA to dial the floating extension number
assigned to the ISDN remote maintenance feature. (
ISDN Remote Floating Extension Number [812])
User-supplied
ISDN TA which
supports CAPI
* Remote access must be enabled through system programming ( Remote Programming [810])
when performing on-site programming via modem or ISDN TA.