EasyManua.ls Logo

Panasonic KX-TDA100

Panasonic KX-TDA100
776 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.17 Maintenance [11]
750 Feature Guide
Feature Guide References
2.4.1 Power Failure Transfer
4.17.4 Miscellaneous [11-4]
Various settings for on-site and remote programming and diagnosis can be specified.
Analog Remote (Modem) Floating Extension Number
Specifies the floating extension number for analog remote maintenance. To enable this setting, an RMT card
must be installed, and Remote Programming on this screen must be enabled.
Default
299
Value Range
Max. 4 digits (consisting of 0–9)
Programming Guide References
None
Feature Guide References
2.3.1 PC Programming
Remote Programming
Enables the system programming, diagnosis, and data upload from a remote location.
Default
Enable
Value Range
Disable, Enable
Programming Guide References
None
Feature Guide References
2.3.1 PC Programming
Password Lock Counter for Remote Programming
Specifies the number of successive incorrect password entries before remote access is locked.
Default
None

Table of Contents

Other manuals for Panasonic KX-TDA100

Related product manuals