2.4 Fault Recovery/Diagnostics
258 Feature Guide
2.4.3 Local Alarm Information
Description
When the PBX detects an error, the System Alarm button on the proprietary telephone (PT) of an extension
which is allowed to use this feature through system programming (a maximum of two extensions per PBX),
lights red. Pressing the button will show the error number on the display. If multiple errors occur, the error
number will be displayed in order of highest priority to lowest. The System Alarm button light turns off
automatically after all error numbers have been displayed.
For details regarding errors and their solutions, refer to the Installation Manual.
[Error Example]
[Explanation]
Conditions
System Alarm Button
Any flexible button can be customized as the System Alarm button.
If an extension allowed to utilize this feature uses PC Console or PC Phone, the alarm information will
also be displayed on the PC.
If an extension allowed to utilize this feature uses PC Console or PC Phone, the alarm information will
be sent to the preprogrammed party via PC Console or PC Phone. PC Console and PC Phone use e-
mail to send the information.
The alarm information will be logged on the Station Message Detail Recording (SMDR) if enabled
through system programming.
The PBX can be automatically diagnosed at a preprogrammed time everyday.
Connection References
4.1.5 Troubleshooting by Error Log
Number in the Example Item Description
(1) Error Code Shows three-digit error code.
(2) Sub Code Shows five-digit sub code (XYYZZ).
X: Cabinet number (1–4)
YY: Slot number (00–11)
ZZ: Physical port number (01–16)
ERR #100 (10000)