EasyManua.ls Logo

Panasonic KX-TDA100 - Utility-T1 Signalling Bit Monitor

Panasonic KX-TDA100
776 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.5 Utility
326 Feature Guide
The items displayed on screen are as follows:
Note
For a list of common errors and solutions, see "4.1.5 Troubleshooting by Error Log" of the Installation
Manual.
To view the error log
•From the Utility menu, select Error Log.
4.5.9 Utility—T1 Signalling Bit Monitor
Displays reference signalling bit information for all channels of the T1 card, by monitoring sent and received
A, B, C and D bits. This utility is intended for use by dealers.
This option is only available at Installer level, and requires that the target T1 card be set to INS status.
While monitoring is being performed, any displayed bits whose value changes from 0 to 1 or vice versa will
be highlighted in red until the next screen refresh is performed.
Major Displays major errors, which affect operation of the whole system,
or result in system failure.
Clear Erases the stored error log information from both the screen and
the PBX.
Item Description
Index The ordinal number assigned to an error record in the current log.
Date The date of the error detection.
Time The time of the error detection.
Error Code The 3-digit error code assigned by the PBX.
Sub Code The 5-digit sub code of the relevant hardware. (1XXYY)
1: Cabinet number
XX: Slot number
KX-TDA100: 00 to 06 (00: MPR slot; 01 to 05: Free slot; 06:
Option slot)
KX-TDA200: 00 to 11 (00: MPR slot; 01 to 10: Free slot; 11:
Option slot)
YY: Physical port number (01 to 16)
For OPB3 card, sub slot number + port number will be
displayed.
Sub slot 1: 11 to 14
Sub slot 2: 21 to 24
Sub slot 3: 31 to 34
Error Message A description of the error.
Button Function

Table of Contents

Other manuals for Panasonic KX-TDA100