4.7 Configuration [1]
Feature Guide 349
Default
30 ms
Value Range
2 × n (n=1–31) ms
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
None
SLT Power Supply
Selects the voltage that enables an SLT to activate the Message Waiting lamp. This setting is only available
with MSLC cards.
Default
85 V
Value Range
85 V, 145 V
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
1.17.1 Message Waiting
Optional Equipment
Indicates whether an Extension Caller ID card is mounted on the SLC8 card (reference only). This is only
available with SLC8 cards.
Default
Current status
Value Range
None, Caller ID
Installation Manual References
2.5.6 EXT-CID Card
Programming Guide References
4.7.1 Slot [1-1]
Feature Guide References
None

Table of Contents

Other manuals for Panasonic KX-TDA100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic KX-TDA100 and is the answer not in the manual?

Panasonic KX-TDA100 Specifications

General IconGeneral
System CapacityUp to 128 extensions
VoIP SupportYes, with optional cards
Digital ExtensionsYes
Analog ExtensionsYes
ISDN SupportYes
Power SupplyAC 100-240 V, 50/60 Hz
Operating Temperature0°C to 40°C
Humidity10% to 90% (non-condensing)
NetworkingYes
TypeHybrid IP PBX
Wireless CapabilityYes
Supported ExtensionsDigital, Analog
Trunk InterfacesAnalog, ISDN
Voicemail CapacityOptional, via voice processing cards