4.7 Configuration [1]
426 Feature Guide
Default
Not stored.
Value Range
Max. 20 characters
Feature Guide References
None
XDP Mode (for S-Hybrid port)
Turns XDP mode on or off for the port.
Default
Off
Value Range
On: XDP enabled (The main telephone and sub telephone have different extension numbers.)
Off: XDP disabled (The main telephone and sub telephone have same extension number [main telephone's
extension number]. = Parallel Mode)
Programming Guide References
None
Feature Guide References
2.1.1 Extension Port Configuration
Parallel Telephone Ringing (for S-Hybrid port)
Specifies whether a sub telephone (SLT) rings at the same time with the main telephone (DPT) for an
incoming call.
Default
Yes
Value Range
Yes, No
Programming Guide References
None
Feature Guide References
1.10.9 Paralleled Telephone
DPT Property—Type (for DPT or S-Hybrid port)
Selects the port type.
To change the port type of an extension port, follow the steps below: