EasyManua.ls Logo

Panasonic KX-UT133-B - Time_Query_Intvl; STUN Settings; Stun_Serv_Addr; Stun_Serv_Port

Panasonic KX-UT133-B
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TIME_QUERY_INTVL
Value Format Integer
Description Specifies the interval, in seconds, between synchronizations with the
NTP server.
Value Range 10–86400
Default Value 43200
Web User Interface Reference Synchronization Interval (Page 87)
5.4.6 STUN Settings
STUN_SERV_ADDR
Value Format String
Description Specifies the IP address or FQDN of the STUN server.
Value Range Max. 127 characters (IP address in dotted-decimal notation or FQDN)
Default Value Empty string
Web User Interface Reference STUN Server Address (Page 79)
STUN_SERV_PORT
Value Format Integer
Description Specifies the port number of the STUN server.
Value Range 1–65535
Default Value 3478
Web User Interface Reference STUN Server Port (Page 80)
STUN_2NDSERV_ADDR
Value Format String
Description Specifies the IP address of the secondary STUN server.
Note
This setting is available only when "STUN_SERV_ADDR" is
specified in IP address notation.
Value Range IP address in dotted-decimal notation
Default Value Empty string
Document Version 2011-06 Administrator Guide 177