Value Format String
Description Specifies the domain name provided by your phone system dealer. The
domain name is the part of the SIP URI that comes after the "@" symbol.
Value Range Max. 127 characters
Default Value Empty string
Web User Interface Reference Service Domain (Page 95)
REG_EXPIRE_TIME_n
Parameter Name Example REG_EXPIRE_TIME_1, REG_EXPIRE_TIME_2, …,
REG_EXPIRE_TIME_4
Value Format Integer
Description Specifies the length of time, in seconds, that the registration remains
valid. This value is set in the "Expires" header of the REGISTER
request.
Value Range 1–4294967295
Default Value 3600
REG_INTERVAL_RATE_n
Parameter Name Example REG_INTERVAL_RATE_1, REG_INTERVAL_RATE_2, …,
REG_INTERVAL_RATE_4
Value Format Integer
Description Specifies the percentage of the "expires" value after which to refresh
registration by sending a new REGISTER message in the same dialog.
Value Range 1–100
Default Value 90
SIP_SESSION_TIME_n
Parameter Name Example SIP_SESSION_TIME_1, SIP_SESSION_TIME_2, …,
SIP_SESSION_TIME_4
Value Format Integer
Description Specifies the length of time, in seconds, that the unit waits before
terminating SIP sessions when no reply to repeated requests is
received. For details, refer to RFC 4028.
Value Range 0, 60–65535 (0: Disable)
Default Value 0
Web User Interface Reference Supports Session Timer (RFC 4028) (Page 100)
216 Administrator Guide Document Version 2011-06
5.7.2 SIP Settings