EasyManuals Logo

Paradox Digiplex EVO EVO192 V7.11 User Manual

Paradox Digiplex EVO EVO192 V7.11
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Version 7.11
24 | Programmable Outputs
Digiplex EVO • Programming Guide
020 Alarm cancelled with user code
000 User codes 001 to 255 001 to 255 001 to 255
001 User codes 256 to 511 000 to 255 000 to 255
002 User codes 512 to 767 000 to 255 000 to 255
003 User codes 768 to 999 000 to 231 000 to 231
255 Any user code Not Used Not Used
021 Alarm cancelled with keyswitch
000 Keyswitch numbers 001 to 032 001 to 032
255 Any keyswitch Not Used Not Used
022 Special disarming
000
Auto arm cancelled 000 000
One-touch Stay/Instant disarm 001 001
Disarming with BabyWare 002 002
Disarming with BabyWare after alarm 003 003
BabyWare canceled alarm 004 004
Future use 005 005
Future use 006 006
Future use 007 007
(InTouch) voice module disarming 008 008
255 Any special disarming event Not Used Not Used
023 Zone bypassed
000
255 = any zone #
Zone numbers
001 to 192 001 to 192
024 Zone in alarm 001 to 192 001 to 192
025 Fire alarm 001 to 192 001 to 192
026 Zone alarm restore 001 to 192 001 to 192
027 Fire alarm restore 001 to 192 001 to 192
028 Early to disarm by user
000 User codes 001 to 255 001 to 255 001 to 255
001 User codes 256 to 511 000 to 255 000 to 255
002 User codes 512 to 767 000 to 255 000 to 255
003 User codes 768 to 999 000 to 231 000 to 231
255 Any user code Not Used Not Used
029 Late to disarm by user
000 User codes 001 to 255 001 to 255 001 to 255
001 User codes 256 to 511 000 to 255 000 to 255
002 User codes 512 to 767 000 to 255 000 to 255
003 User codes 768 to 999 000 to 231 000 to 231
255 Any user code Not Used Not Used
030 Special alarm 000
Emergency panic (Keys 1 & 3) 000 000
Medical panic (Keys 4 & 6) 001 001
Fire panic (Keys 7 & 9) 002 002
Recent closing 003 003
Police code 004 004
Zone shutdown 005 005
Future use 006 006
Future use 007 007
TLM alarm 008 008
Central communication failure alarm 009 009
Module tamper alarm 010 010
Missing GSM module alarm 011 011
030
(cont.)
Special alarm
(cont.)
000
(cont.)
GSM no service alarm 012 012
Missing IP module alarm 013 013
IP no service alarm 014 014
Missing voice module alarm 015 015
255 Any special alarm event Not Used Not Used
Table 16: List of Event and Feature Groups (Continued)
A
Event Group
Event
B
Feature Group
Feature
C
Start #
D
End #

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Digiplex EVO EVO192 V7.11 and is the answer not in the manual?

Paradox Digiplex EVO EVO192 V7.11 Specifications

General IconGeneral
Zones8 on board, expandable to 192
Partitions8
User Codes999
PGM Outputs5 on board, expandable to 250
Remote Firmware UpgradeYes
ExpandableYes
Memory2048 events
Event Buffer2048 events
PGMs5 on board, expandable to 250
CommunicationSupports GSM/GPRS/IP reporting
Battery Backup7 Ah
Number of Zones8 (expandable to 192)
Operating Temperature0°C to 50°C (32°F to 122°F)
Humidity5% to 90% non-condensing
CompatibilityParadox EVO series

Related product manuals