87
13. APPENDIX
13.1 Warning and Error Messages
WarningMessage Meaning Whattodo
Outoftiltrange Displayedwhentheinstrumentistilted
beyondtheverticalcompensationrange
(±3ʼ)incaseautomaticcompensationis
selected.
Whenitisproperlyleveled,thismessage
maybetemporarilydisplayedifthe
instrumentisturnedtoofast.
Re-levelthe
instrument.
Repairisneededif
themessageis
displayedwhenitis
properlylevelled.
Excessdata Theinputdataexceedstheallowable
range.
Pressthe[ESC]key
andenterthecorrect
data.
Outofrange
(whenbeinglit)
Thismessageisdisplayedifalong
distancewhichisfarbeyondmeasurable
distanceofR-2500DNseriesismeasured
withawrongtargetmode.
Pleaseselectacorrecttargetthen
measure.
Ifawrongtargetisselected,acorrect
distancecannotbemeasured.
Selectthecorrect
targetmode.
Outofrange
(whenflashing)
Themeasurementdistanceislessthan
1.5minReflectorsheetmode.
Themeasurementdistanceislessthan
5minPrismmode.
Selectalongerpoint,
oruseatape
measurer.
Unsuitable
Condition
Undertoostrongsunlight.
Unstablelightvalueowingtoshimmeror
obstacles.
Reflectorsheet,TargetandPrismdonot
facetheinstrument.
Reflectorsheet,TargetandPrismarenot
correctlysighted.
Measurementrangeisoverin
Reflectorlessmode.
Sufficientsignaldoesnotreturnby
sightingsharpedgeetc.atReflectorless
mode.
Changetheobject
thathasmuchbetter
reflectivityorusea
prism,orwaituntil
thesunactivityhas
weakened.
Li-batt.voltageis
low.
•TheDateClockispoweredbythe
built-inlithiumbattery.
•Thelithiumbatteryneedstobe
replacedinfiveyears.
Havethelithium
batteryreplacedby
thedealerfromwhom
theinstrumentwas
purchased.